用戶【長庚蘇志燮】點評問題和點評內容

【評論主題】57.若以portable X光機執行模擬攝影作業,則無法正確取得Co-60治療機的何種參數?①SSD ②SAD ③SFD(A)僅①(B)僅②(C)僅③(D)①②③

【評論內容】

SFD – Source-to-Film Distance – is the distance between the radiation source and the film in radiographic testing, as measured in the direction of the beam.

【評論主題】9.假設20 keV的X光和軟組織(Z=7.4)發生光電效應的相對機率為1,則 40 keV的X光和軟組織(Z=7.4)發生光電效應的相對機率為何?(A)1/2(B)2(C)1/4(D)1/8

【評論內容】光電效應:與E3成反比,與Z3成正比書中寫了一堆@#$%&*@##$主要還是看圖,鉛跟水質量係數比約為1000:1,鉛跟水原子序比82:7.5,約10:1。

【評論主題】57.若以portable X光機執行模擬攝影作業,則無法正確取得Co-60治療機的何種參數?①SSD ②SAD ③SFD(A)僅①(B)僅②(C)僅③(D)①②③

【評論內容】

SFD – Source-to-Film Distance – is the distance between the radiation source and the film in radiographic testing, as measured in the direction of the beam.

【評論主題】9.假設20 keV的X光和軟組織(Z=7.4)發生光電效應的相對機率為1,則 40 keV的X光和軟組織(Z=7.4)發生光電效應的相對機率為何?(A)1/2(B)2(C)1/4(D)1/8

【評論內容】光電效應:與E3成反比,與Z3成正比書中寫了一堆@#$%&*@##$主要還是看圖,鉛跟水質量係數比約為1000:1,鉛跟水原子序比82:7.5,約10:1。

【評論主題】49 某一物質對 70 keV X 光的衰減係數(attenuation coefficient)為 0.3 cm-1,則此物質 1 個半值層(HVL)等於多少鬆弛長度(relaxation leng

【評論內容】

沒錯1/0.3=3.333333為鬆弛長度0.693/0.3為HVL(0.693/0.3)*(0.3/1)為答案0.693約0.7可參考放物105-2-61 放物107-1-61 

定義:

鬆弛長度即為輻射率衰減為1/e倍的屏蔽厚度

【評論主題】7.下列有關成對發生作用(pair production)的敘述,何者正確?(A)入射光子能量至少必須大於0.511 MeV(B)入射光子與靶物質原子核的電磁場發生交互作用(C)作用機率與靶物質的原子

【評論內容】

A)1.022MeVC)與原子序平方成正比D)其作用產生的電子與正子非對向,

   是正子與外面電子產生互毀作用,

   產生2個對向(180度)0.511MeV的光子。