13.有關環氧乙烷(ethylene oxide,ETO)氣體滅菌法之敘述,下列何者錯誤?
(A)低溫滅菌劑,滅菌溫度 29~65℃
(B)ETO氣體的濃度 450~1200 mg/L, 相對濕度:45%~85%
(C)避免產生 ethylene glycol(乙二醇)產生組織傷害,消毒物品必須乾燥去除水分
(D)依美國 Occupational Safety and Health Administration(OSHA)標準工作人員 8 小時最大暴露劑量不得大於 5 ppm

參考答案

答案:D
難度:適中0.526316
統計:A(7),B(5),C(0),D(30),E(0)

用户評論

周庭彣】評論

Occupational Safety and Health Administration"8-hour time-weighted average (TWA)." The employer shall ensure that no employee is exposed to an airborne concentration of EtO in excess of one (1) part EtO per million parts of air (1 ppm) as an (8)-hour time-weighted average (8-hour TWA)."Excursion limit." The employer shall ensure that no employee is exposed to an airborne concentration of EtO in excess of 5 parts of EtO per million parts of air (5 ppm) as averaged over a sampling period of fifteen (15) minute...