【用戶】Klose Liu
【年級】國二下
【評論內容】TBI protocols do not require skin sparing. Instead, a bolus or a beam spoiler is specified to bring the surface dose to at least 90% of the prescribed TBI dose. A large spoiler screen of 1- to 2-cm-thick acrylic is sufficient to meet these requirements, provided the screen is placed as closeas possible to the patient surface. 文字出處:khans 5th p406
【用戶】海馬迴
【年級】小二上
【評論內容】 【全身光子放射治療(total body irradiation, TBI)】主要目的:抑制患者的免疫系統適合TBI的疾病:白血病、再生不良性貧血、淋巴瘤、多發性骨隨瘤、自體免疫疾病、先天性代謝缺陷使用 beam spoiler 的目的:增加光子射線皮膚區的劑量 (需達到90%的處方劑量)常使用的劑量率範圍為:5~10 cGy/min劑量率選擇在 5~10 cGy/min主要目的: 降低病患肺部 pneumonitis 的副作用(以上為歷屆TBI考過的重點整理)放射治療物理學(KHAN's The Physics of Radiation Therapy)第五版 P.406-------------------------------------(如果以上詳解對你有幫助也請幫我按個讚喔謝謝你><)
【用戶】Klose Liu
【年級】國二下
【評論內容】TBI protocols do not require skin sparing. Instead, a bolus or a beam spoiler is specified to bring the surface dose to at least 90% of the prescribed TBI dose. A large spoiler screen of 1- to 2-cm-thick acrylic is sufficient to meet these requirements, provided the screen is placed as closeas possible to the patient surface. 文字出處:khans 5th p406
【用戶】海馬迴
【年級】小二上
【評論內容】 【全身光子放射治療(total body irradiation, TBI)】主要目的:抑制患者的免疫系統適合TBI的疾病:白血病、再生不良性貧血、淋巴瘤、多發性骨隨瘤、自體免疫疾病、先天性代謝缺陷使用 beam spoiler 的目的:增加光子射線皮膚區的劑量 (需達到90%的處方劑量)常使用的劑量率範圍為:5~10 cGy/min劑量率選擇在 5~10 cGy/min主要目的: 降低病患肺部 pneumonitis 的副作用(以上為歷屆TBI考過的重點整理)放射治療物理學(KHAN's The Physics of Radiation Therapy)第五版 P.406-------------------------------------(如果以上詳解對你有幫助也請幫我按個讚喔謝謝你><)