問題詳情

3.下列那些麻醉相關監視器對靜脈空氣栓塞(venous air embolism)偵測之敏感度(sensitivity),由高至低排列順序為何?①capnometer ②precordial doppler ③oximeter ④transesophageal echocardiograph
(A)①②③④
(B)②①③④
(C)②③①④
(D)④②①③

參考答案

答案:D
難度:適中0.642857
統計:A(4),B(0),C(0),D(18),E(0)

用户評論

乖乖唸書】評論

摘錄自96年麻專考題**靜脈空氣栓塞常出現在神外手術(常見之來源為transverse sinus & saggital sinus)麻專考題

霸氣阿宏】評論

Transesophageal echocardiography (TEE) and precordial Doppler ultrasound were the most sensitive monitoring methods detecting 0.19 and 0.24 ml X kg-1 of air, respectively. TEE detected air during six infusions in which the Doppler failed to do so. Transesophageal echocardiography and transcutaneous O2 and CO2 monitoring for detection of venous air embolism.Glenski JA, Cucchiara RF, Michenfelder JD.AbstractThe sensitivities of current monitoring methods for detection of air embolism were compared in eight anesthetized dogs. Air was infused at controlled rates of 0.001 and 0.005 ml X kg-1 X m...